Initial content, migrated from the aml gateway rpi7-am-1
This commit is contained in:
@@ -1,3 +1,13 @@
|
||||
# bar-detection
|
||||
|
||||
Detects bars entering and leaving the oven and writes in-detect-oven / out-detect-oven
|
||||
Runs continuously, once a second. Detects a bar entering the oven on the rising edge of the
|
||||
entry photocell `Hin` (3) and writes a pulse to `in-detect-oven` (11). Detects a bar leaving
|
||||
when the reading it calls `THact` crosses above 600 and writes a pulse to `out-detect-oven`
|
||||
(12). Both outputs are i7state pulse signals, consumed by `bar-tracker`.
|
||||
|
||||
**Known mismatch, kept as it runs today:** `signals.yml` maps id 17 to the name `THact`, but
|
||||
signal 17 is `THprocess`; the real `THact` is 18. The exit trigger therefore fires on
|
||||
`THprocess`. Correcting it means changing the id to 18 in `signals.yml` and tagging a new
|
||||
version.
|
||||
|
||||
Runs in `docker.izazpi.cloud/aml/aml-python`; the version is in `schedule.yaml`.
|
||||
|
||||